USA
For information on pricing, please contact your local FuelMaker Dealer.
|
Model |
Max Discharge Pressure (psi) |
Hourly Flow Rate (gge) |
Hourly Flow Rate (pge) |
Flow Rate (scfm) |
Gas Inlet Pressure (psi) |
|
FMQ-10 |
3,000 |
3.9 |
5.3 |
8.0 |
1 to 1¼ * |
|
FMQ-8-36 |
3,600 |
3.7 |
5.0 |
7.6 |
1 to 1¼* |
|
FMQ-2 |
3,000 |
1.0 to 1.1 |
1.3 to 1.5 |
2.0 to 2.2 |
¼ to 2.0 |
|
FMQ 2-36 |
3,600 |
0.9 |
1.3 |
1.9 |
¼ to ½ |
|
psi - pounds per square inch |
scfm – standard cubic feet per minute |
|
pge – propane gallon equivalent |
* optional ¼ psi available |
|
gge – gasoline gallon equivalent |
|
|
|
FMQ-10, FMQ-8-36 |
|
ELECTRICAL |
|
|
|
Electrical Supply |
|
240 Volts AC, Single Phase, 60 Hz |
|
Full Load Amperage |
|
28 Amps |
|
Average Power Consumption over Typical Fill Cycle |
|
4.0 to 4.8 kWh |
|
Classification |
|
General Purpose |
|
MECHANICAL |
|
|
|
Dimensions (LxWxH) |
|
44”x39”x39” |
|
Unit Weight |
|
580 lbs. |
|
Ambient Temperature Rating |
|
-40ºF to +113ºF |
|
Guaranteed Service Interval (Refer to Warranty) |
|
3,000 Hrs. |
|
Required Distance from Storage |
|
15 Ft. |
|
Noise Level |
|
66 dBA @ 16.5 ft. |
FMQ-2, FMQ-2-36 |
|
ELECTRICAL |
|
|
|
Electrical Supply |
|
240 Volts AC, Single Phase, 60 Hz |
|
Full Load Amperage |
|
7 Amps |
|
Average Power Consumption over Typical Fill Cycle |
|
1.0 to 1.2 kWh |
|
Classification |
|
General Purpose |
|
MECHANICAL |
|
|
|
Dimensions (LxWxH) |
|
21”x20”x39” |
|
Unit Weight |
|
145 lbs. |
|
Ambient Temperature Rating |
|
-40ºF to +113ºF |
|
Guaranteed Service Interval (Refer to Warranty) |
|
3,000 Hrs. |
|
Required Distance from Storage |
|
15 Ft. |
|
Noise Level |
|
49 dBA @ 16.5 ft |
CANADA
For information on pricing, please contact your local FuelMaker Dealer.
|
Model |
Max Discharge Pressure (psi) |
Hourly Flow Rate (gle) |
Hourly Flow Rate (ple) |
Flow Rate (scfm) |
Gas Inlet Pressure (psi) |
|
FMQ-10 |
3,000 |
14.8 |
20.0 |
8.0 |
1 to 1¼ * |
|
FMQ-8-36 |
3,600 |
14 |
19 |
7.6 |
1 to 1¼* |
|
FMQ-2 |
3,000 |
3.7 to 4.1 |
5.0 to 5.5 |
2.0 to 2.2 |
¼ to 2.0 |
|
FMQ 2-36 |
3,600 |
3.5 |
4.7 |
1.9 |
¼ to ½ |
|
psi – pounds per square inch |
scfm – standard cubic feet per minute |
|
ple – propane litre equivalent |
* optional ¼ psi available |
|
gle – gasoline litre equivalent |
|
|
|
FMQ-10, FMQ-8-36 |
|
ELECTRICAL |
|
|
|
Electrical Supply |
|
240 Volts AC, Single Phase, 60 Hz |
|
Full Load Amperage |
|
28 Amps |
|
Average Power Consumption over Typical Fill Cycle |
|
4.0 to 4.8 kWh |
|
Classification |
|
General Purpose |
|
MECHANICAL |
|
|
|
Dimensions (LxWxH) |
|
1118x990x990 mm |
|
Unit Weight |
|
263 kg |
|
Ambient Temperature Rating |
|
-40ºC to +45ºC |
|
Guaranteed Service Interval (Refer to Warranty) |
|
3,000 Hrs. |
|
Required Distance from Storage |
|
3 Metres |
|
Noise Level |
|
66 dBA @ 5m |
FMQ-2-36, FMQ-2 |
|
ELECTRICAL |
|
|
|
Electrical Supply |
|
240 Volts AC, Single Phase, 60 Hz |
|
Full Load Amperage |
|
7 Amps |
|
Average Power Consumption over Typical Fill Cycle |
|
1.0 to 1.2 kWh |
|
Classification |
|
General Purpose |
|
MECHANICAL |
|
|
|
Dimensions (LxWxH) |
|
540x500x990 mm |
|
Unit Weight |
|
66 kg |
|
Ambient Temperature Rating |
|
-40ºC to +45ºC |
|
Guaranteed Service Interval (Refer to Warranty) |
|
3,000 Hrs. |
|
Required Distance from Storage |
|
3 Metres |
|
Noise Level |
|
49 dBA @ 5m |
INTERNATIONAL
|
Model |
Max Discharge Pressure (Mpa) |
Hourly Flow Rate (gle) |
Hourly Flow Rate (ple) |
Flow Rate (m3/h) |
Gas Inlet Pressure (kPa) |
|
At 60 Hz |
|
|
|
|
|
|
FMQ-10 |
20.7 |
14.8 |
20.0 |
13.6 |
6.9 to 8.6* |
|
FMQ-8-36 |
24.8 |
14.1 |
19.0 |
12.9 |
6.9 to 8.6* |
|
FMQ-2 |
20.7 |
3.7 to 4.1 |
5.0 to 5.5 |
3.4 to 3.7 |
1.7 to 14 |
|
FMQ 2-36 |
24.8 |
3.5 |
4.7 |
3.2 |
1.7 to 3.5 |
|
At 50 Hz |
|
|
|
|
|
|
FMQ-10 |
20.7 |
11.8 |
16.0 |
10.9 |
6.9 to 8.6* |
|
FMQ-8-36 |
24.8 |
11.2 |
15.2 |
10.3 |
6.9 to 8.6* |
|
FMQ-2 |
20.7 |
3.0 to 3.3 |
4.0 to 4.4 |
2.7 to 3.0 |
1.7 to 14 |
|
FMQ 2-36 |
24.8 |
2.8 |
3.8 |
2.6 |
1.7 to 3.5 |
|
Mpa – megapascals |
m3/h – metres cubed per hour |
|
ple – gasoline litre equivalent |
kPa – kilopascals |
|
gle – propane litre equivalent |
* optional ¼ psi available |
FMQ-10, FMQ-8-36 |
|
ELECTRICAL |
|
|
|
|
Full load Amperage (60/50 Hz) |
|
28/26 Amps |
|
|
Average Power Consumption over Typical Fill Cycle |
|
3.6 to 4.8 kWh |
|
|
Electrical Supply (both models) |
|
240 Volts AC, Single Phase, 60 Hz 220 Volts AC, Single Phase, 50 Hz |
|
MECHANICAL |
|
|
|
Dimensions (LxWxH) |
|
1118x990x990 mm |
|
Unit Weight |
|
263 kg |
|
Ambient Temperature Rating |
|
-40ºC to +45ºC |
|
Guaranteed Service Interval (Refer to Warranty) |
|
3,000 Hrs. |
|
Noise Level |
|
66 dBA @ 5m |
|
FMQ-2-36, FMQ-2 |
|
ELECTRICAL |
|
|
|
|
Full load Amperage (60/50 Hz) |
|
7.0/6.5 Amps |
|
|
Average Power Consumption over Typical Fill Cycle |
|
0.9 to 1.2 kWh |
|
|
Electrical Supply (all models) |
|
240 Volts AC, Single Phase, 60 Hz 220 Volts AC, Single Phase, 50 Hz |
|
MECHANICAL |
|
|
|
Dimensions (LxWxH) |
|
540x500x990 mm |
|
Unit Weight |
|
66 kg |
|
Ambient Temperature Rating |
|
-40ºC to +45ºC |
|
Guaranteed Service Interval (Refer to Warranty) |
|
3,000 Hrs. |
|
Noise Level |
|
49 dBA @ 5m |
| |