USA  |  Canada  |  International
Canadian Specifications

For information on pricing, please contact your local FuelMaker Dealer.

Model

Max Discharge Pressure (psi)

Hourly Flow Rate (gle)

Hourly Flow Rate (ple)

Flow Rate (scfm)

Gas Inlet Pressure (psi)

FMQ-10

  3,000

  18.5

  25

  10.0

  1 to 1¼ *

FMQ-8-36

  3,600

  14

  19

  7.6

  1 to 1¼*

FMQ-2

  3,000

  3.7 to 4.1

  5.0 to 5.5

  2.0 to 2.2

  ¼ to 2.0

FMQ 2-36   3,600   3.5   4.7   1.9   ¼ to ½

FMQ-2.5

  3,000

  4.6

  6.25

  2.5

  ¼ to ½

psi – pounds per square inch

scfm – standard cubic feet per minute

ple – propane litre equivalent

* optional ¼ psi available

gle – gasoline litre equivalent

FMQ-10, FMQ-8-36

Electrical

Electrical Supply

240 Volts AC, Single Phase, 60 Hz

Full Load Amperage

28 Amps

Average Power Consumption over Typical Fill Cycle

4.0 to 4.8 kWh

Classification

General Purpose

Mechanical

Dimensions (LxWxH)

848 x 1228 x 813 mm

Unit Weight

263 kg

Ambient Temperature Rating

-40ºC to +45ºC

Mandatory Service Interval

4,000 Hrs.

Required Distance from Storage

3 Metres

Noise Level

66 dBA @ 5m

FMQ-2-36, FMQ-2, FMQ-2.5

Electrical

Electrical Supply

240 Volts AC, Single Phase, 60 Hz

Full Load Amperage

7 to 8 Amps

Average Power Consumption over Typical Fill Cycle

1.0 to 1.5 kWh

Classification

General Purpose

Mechanical

Dimensions (LxWxH)

540 x 500 x 990 mm

Unit Weight

66 kg

Ambient Temperature Rating

-40ºC to +45ºC

Mandatory Service Interval

4,000 Hrs.

Required Distance from Storage

3 Metres

Noise Level

49 dBA @ 5m