USA Specifications
For information on pricing, please contact your local FuelMaker Dealer.
|
Model |
Max Discharge Pressure (psi) |
Hourly Flow Rate (gge) |
Hourly Flow Rate (pge) |
Flow Rate (scfm) |
Gas Inlet Pressure (psi) |
|
FMQ-10 |
3,000 |
4.9 |
6.6 |
10.0 |
1 to 1¼ * |
|
FMQ-8-36 |
3,600 |
3.7 |
5.0 |
7.6 |
1 to 1¼* |
|
FMQ-2 |
3,000 |
1.0 to 1.1 |
1.3 to 1.5 |
2.0 to 2.2 |
¼ to 2.0 |
| FMQ 2-36 |
3,600 |
0.9 |
1.3 |
1.9 |
¼ to ½ |
|
FMQ-2.5 |
3,000 |
1.2 |
1.6 |
2.5 |
¼ to ½ |
|
psi - pounds per square inch |
scfm – standard cubic feet per minute |
|
pge – propane gallon equivalent |
* optional ¼ psi available |
|
gge – gasoline gallon equivalent |
|
|
|
FMQ-10, FMQ-8-36 |
|
Electrical |
|
|
|
Electrical Supply |
|
240 Volts AC, Single Phase, 60 Hz |
|
Full Load Amperage |
|
28 Amps |
|
Average Power Consumption over Typical Fill Cycle |
|
4.0 to 4.8 kWh |
|
Classification |
|
General Purpose |
|
Mechanical |
|
|
|
Dimensions (LxWxH) |
|
33”x48”x32” |
|
Unit Weight |
|
580 lbs. |
|
Ambient Temperature Rating |
|
-40ºF to +113ºF |
|
Mandatory Service Interval |
|
4,000 Hrs. |
|
Required Distance from Storage |
|
15 Ft. |
|
Noise Level |
|
66 dBA @ 16.5 ft. |
FMQ-2, FMQ-2-36, FMQ-2.5 |
|
Electrical |
|
|
|
Electrical Supply |
|
240 Volts AC, Single Phase, 60 Hz |
|
Full Load Amperage |
|
7 to 8 Amps |
|
Average Power Consumption over Typical Fill Cycle |
|
1.0 to 1.5 kWh |
|
Classification |
|
General Purpose |
|
Mechanical |
|
|
|
Dimensions (LxWxH) |
|
21”x20”x39” |
|
Unit Weight |
|
145 lbs. |
|
Ambient Temperature Rating |
|
-40ºF to +113ºF |
|
Mandatory Service Interval |
|
4,000 Hrs. |
|
Required Distance from Storage |
|
15 Ft. |
|
Noise Level |
|
49 dBA @ 16.5 ft |
|